PG95230G-AT
  • PG95230G-AT

PG95230G-AT

Aten

ATEN PG95230G, Metered, 0U, Three-phase, Black, LCD, 30 AC outlet(s)

CHF1,180.5
Tax included
CHF1,092.0 Tax excluded
Delivery in several days
Quantity
Will be ordered for you

Description
When maintaining operating uptime in a data center or server room, sustainable energy efficiency can make all the difference. The implementation of effective power management often involves improvements at both the hardware and software level. As the trend for 3-phase power grows due to its efficiency to generate, transfer, and distribute electricity, ATEN is introducing its latest PG series of PDUs, available in IEC socket configuration, that are designed with 0U rack housing to accommodate the increasing demand for power to high-density IT equipment in server rooms and data centers. Each PG95230 PDU, utilizing an ARM-Cortex A8 processor, is equipped with 30 port outlets capable of running at higher voltages, powers up all connected equipment in less than 10 seconds once plugged in, and delivers the most accurate kWh energy usage data (+/-1%) for better power consumption habits, baselines, and initiative tracking. With energy saving in mind, the PG95230 is purposed to enable lower energy consumption for best practice in a network infrastructure, while promoting up to 70.65 kg (131.4 kw equivalent of power consumption) of reduced CO2 emission, reduced electricity expenses, and lower carbon taxes to pay each year.

Secure Locking Enhancement
The outlets can be protected with a secure lock to prevent power cords from becoming unplugged due to vibration or human errors.

Real-time Alerts via LCD Display
The illuminated LCD display can display warnings to alert users of unusual power states.

Hot-Swappable Function
The LCD console panel is hot-swappable and can be removed, replaced, or repaired without powering down a mission-critical connected load.

Dual LAN Ports for Scalable Network Setup
The PG95230 is equipped with dual LAN ports (e.g. Internet and Intranet) supporting up to 1G Ethernet connection, and can be cascaded to connect up to 64 PDUs, saving expense on installing extra network switches to incorporate network connections while sparing more rack space to accommodate more IT equipment in an expandable network.

Environment Sensors
The Sensor port enables RJ-45 connectivity to connect or daisy-chain up to 8 environment sensors for monitoring and management of temperature, humidity, airflow, differential air pressure, and leaks, featuring alerts for potential threats.

Flexible On-Site Network Operation
For quick operation, connecting a serial device to the PDU with its COM port provides another means to undertake communication via CLI commands. In addition, the same port is also functional as a PON port, available for Ethernet connection to a KN series KVM over IP Switch to centralize power management of up to 16 daisy-chained PDUs.

Networkable via WiFi
The PG95230 can be networked via connection to a USB WiFi dongle to perform DCIM, firmware upgrade, log export, quick configuration, and more.

Adjustable Power Cord for Flexible In-Rack Installation
The PG95230 comes with an adjustable power cord built in to the unit capable of 90-degree rotation to allow flexible in-rack installation, resulting in better cable organization.

DCIM Monitoring
Integrated with ATEN’s eco DC – a PC- and web-based tool for optimized Data Center Infrastructure Management (DCIM) – power distribution, energy, and environmental data from PDUs and connected devices can be monitored via a friendly web GUI for smart power management.

Colored Panel for Smarter Power Monitoring
The PG series PDUs feature a LCD console panel in default red and can be re-colored with options of yellow, purple, blue, and green through optional purchase of colored stickers. These color codes make it easier to differentiate between power feed settings and also speed up troubleshooting in case of unexpected failures.

Applications
The PG series 3-Phase PDUs are perfectly suited to server rack installation requiring energy-efficient power distribution to high-density IT equipment in a server room or data center.

ATEN PG95230G. PDU types: Metered, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 30 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: IEC309. Cable length: 118.1" (3 m), Security algorithms: TLS. Monitoring: Current, Humidity, Power, Temperature, Voltage, Supported network protocols: IPv6, SMS, Management protocols: TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, ARP, NTP, DNS, Auto Sense, Ping, SNMP V1&V2&V3, Telnet,.... Nominal input voltage: 400 V, Maximum current: 16 A, AC input frequency: 50 - 60 Hz
PDU typesMetered
Rack capacity0U
TypeThree-phase
Product colorBlack
DisplayLCD
AC outlets quantity30 AC outlet(s)
AC outlet typesC13 coupler, C19 coupler
Power plugIEC309
Ethernet LAN (RJ-45) ports4
USB ports quantity1
Daisy chainYes
Reset buttonYes
Cable length118.1" (3 m)
Security algorithmsTLS
MonitoringCurrent, Humidity, Power, Temperature, Voltage
Supported network protocolsIPv6, SMS
Management protocolsTCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, ARP, NTP, DNS, Auto Sense, Ping, SNMP V1&V2&V3, Telnet, Modbus
Nominal input voltage400 V
Maximum current16 A
AC input frequency50 - 60 Hz
Nominal output voltage230 V
Load capacity11084 VA
Number of phases3
Circuit breakerNo
Compliance certificatesCE
Operating temperature (T-T)0 - 60 °C
Storage temperature (T-T)-20 - 60 °C
Operating relative humidity (H-H)0 - 80%
Storage relative humidity (H-H)0 - 80%
Width2.2" (56 mm)
Depth70.5" (1790 mm)
Height2.68" (68 mm)
Weight16.2 lbs (7.34 kg)
ManualYes
Rack mount kitYes
Package weight21.4 lbs (9.72 kg)
Package width9.02" (229 mm)
Package depth76.6" (1945 mm)
Package height7.05" (179 mm)
Package volume79853.5074 cm³
Master (outer) case net weight16.5 lbs (7.5 kg)
Master (outer) case width9.02" (229 mm)
Master (outer) case length76.6" (1945 mm)
Master (outer) case height7.05" (179 mm)
Master (outer) case weight22.3 lbs (10.1 kg)
Master (outer) case volume79853.5074 cm³
Sustainability complianceYes
Product Details
2026-06-17
New

Data sheet

Type
Three-phase
Product color
Black
Ethernet LAN (RJ-45) ports
4
Cable length
118.1" (3 m)
Weight
16.2 lbs (7.34 kg)
AC input frequency
50 - 60 Hz
Width
2.2" (56 mm)
Height
2.68" (68 mm)
Depth
70.5" (1790 mm)
Package weight
21.4 lbs (9.72 kg)
Master (outer) case width
9.02" (229 mm)
Master (outer) case length
76.6" (1945 mm)
Master (outer) case height
7.05" (179 mm)
Master (outer) case weight
22.3 lbs (10.1 kg)
Package width
9.02" (229 mm)
Package depth
76.6" (1945 mm)
Package height
7.05" (179 mm)
Operating temperature (T-T)
0 - 60 °C
Storage temperature (T-T)
-20 - 60 °C
Operating relative humidity (H-H)
0 - 80%
Storage relative humidity (H-H)
0 - 80%
USB ports quantity
1
Rack capacity
0U
Display
LCD
Sustainability compliance
Yes
Manual
Yes
AC outlets quantity
30 AC outlet(s)
Compliance certificates
CE
Security algorithms
TLS
Supported network protocols
IPv6, SMS
Maximum current
16 A
Nominal output voltage
230 V
Reset button
Yes
Master (outer) case net weight
16.5 lbs (7.5 kg)
Management protocols
TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, ARP, NTP, DNS, Auto Sense, Ping, SNMP V1&V2&V3, Telnet, Modbus
AC outlet types
C13 coupler, C19 coupler
Nominal input voltage
400 V
Package volume
79853.5074 cm³
PDU types
Metered
Power plug
IEC309
Load capacity
11084 VA
Rack mount kit
Yes
Master (outer) case volume
79853.5074 cm³
Daisy chain
Yes
Monitoring
Number of phases
3
Circuit breaker
No

Specific References

EAN13
4710469342950
MPN
PG95230G-AT
16 other products in the same category:
PE1216G-AX-G

Brand: Aten

PE1216G-AX-G

ATEN PE1216G-AX-G, Metered, Metal, Black, 16 AC outlet(s), C13 coupler, C20 coupler
CHF173.1 tax incl.
CHF160.1 tax excl.
More PE1216G-AX-G
Will be ordered for you
PE8324G3-AX

Brand: Aten

PE8324G3-AX

ATEN PE8324, Metered, Switched, Black, 24 AC outlet(s), C13 coupler, C19 coupler, IEC 60309, 63" (1.6 m)
CHF1,105.0 tax incl.
CHF1,022.2 tax excl.
More PE8324G3-AX
Will be ordered for you
SX-DS-1011I

Reference: 510052876

Brand: SurgeX

SX-DS-1011I

Defender Power Protection, 10A / 240V, 8x IEC C13
CHF410.1 tax incl.
CHF379.4 tax excl.
More SX-DS-1011I
Will be ordered for you
PE1324G-AX

Brand: Aten

PE1324G-AX

ATEN PE1324G-AX, Metered, Metal, Black, 24 AC outlet(s), C13 coupler, IEC 60309
CHF359.8 tax incl.
CHF332.8 tax excl.
More PE1324G-AX
Will be ordered for you
PE1116SG-AT-G

Brand: Aten

PE1116SG-AT-G

ATEN PE1116SG-AT-G, Basic, Metered, 0U, Black, LCD, 16 AC outlet(s), C13 coupler
CHF214.1 tax incl.
CHF198.1 tax excl.
More PE1116SG-AT-G
Will be ordered for you
PG96330G-AT

Brand: Aten

PG96330G-AT

ATEN PG96330G, Metered, Switched, 0U, Three-phase, Black, LCD, 30 AC outlet(s)
CHF1,657.3 tax incl.
CHF1,533.1 tax excl.
More PG96330G-AT
Will be ordered for you
PE0110SG-AT-G

Reference: PE0110SG-AT-G

Brand: Aten

PE0110SG-AT-G

ATEN PE0110SG, Basic, 1U, Black, 10 AC outlet(s), C13 coupler, 100 - 240 V
CHF92.2 tax incl.
CHF85.3 tax excl.
More PE0110SG-AT-G
Will be ordered for you
PE0118SG-AT-G

Brand: Aten

PE0118SG-AT-G

ATEN PE0118SG, Basic, 1U, Aluminum, Black, 18 AC outlet(s), C13 coupler
CHF125.3 tax incl.
CHF115.9 tax excl.
More PE0118SG-AT-G
Will be ordered for you
PE0316SG-AT

Brand: Aten

PE0316SG-AT

ATEN PE0316SG-AT, Basic, 0U, Aluminum, Black, 16 AC outlet(s), C13 coupler
CHF254.0 tax incl.
CHF235.0 tax excl.
More PE0316SG-AT
Will be ordered for you
SX-AEP-1011I

Reference: 585460005

Brand: SurgeX

SX-AEP-1011I

Axess ELITE+ IP Controlled Power Management, 10A / 240V, 11x IEC C13, 19", 1U Smart PDU with Advanced Series Mode Power Protection
CHF2,863.6 tax incl.
CHF2,649.0 tax excl.
More SX-AEP-1011I
Will be ordered for you
PG98330G-AT

Brand: Aten

PG98330G-AT

ATEN PG98330G-AT, Metered, Switched, 0U, Three-phase, Black, LCD, 30 AC outlet(s)
CHF1,543.1 tax incl.
CHF1,427.5 tax excl.
More PG98330G-AT
Will be ordered for you
PE0116SG-AT-G

Brand: Aten

PE0116SG-AT-G

ATEN PE0116SG, Basic, 0U, Aluminum, Black, 16 AC outlet(s), C13 coupler
CHF129.7 tax incl.
CHF120.0 tax excl.
More PE0116SG-AT-G
Will be ordered for you
PE0324SG-AT

Brand: Aten

PE0324SG-AT

ATEN PE0324SG-AT, Basic, 0U, Aluminum, Black, 24 AC outlet(s), C13 coupler, C19 coupler
CHF288.5 tax incl.
CHF266.9 tax excl.
More PE0324SG-AT
Will be ordered for you
PE1224SG-AT-G

Brand: Aten

PE1224SG-AT-G

ATEN PE1224SG-AT-G, Basic, Metered, 0U, Black, LCD, 24 AC outlet(s), C13 coupler, C19 coupler
CHF258.1 tax incl.
CHF238.8 tax excl.
More PE1224SG-AT-G
Will be ordered for you
PE1316SG-AT

Brand: Aten

PE1316SG-AT

ATEN PE1316SG-AT, Basic, Metered, 0U, Black, LCD, 16 AC outlet(s), C13 coupler
CHF368.0 tax incl.
CHF340.4 tax excl.
More PE1316SG-AT
Will be ordered for you
PE1216SG-AT-G

Brand: Aten

PE1216SG-AT-G

ATEN PE1216SG-AT-G, Basic, Metered, 0U, Black, LCD, 16 AC outlet(s), C13 coupler
CHF219.7 tax incl.
CHF203.2 tax excl.
More PE1216SG-AT-G
Will be ordered for you