Automatic internal bypassSupplies utility power to the connected loads in the event of a UPS power overload or fault.
2 years repair or replace
Automatic restart of loads after UPS shutdownAutomatically starts up the connected equipment upon the return of utility power.
ECO ModeOperating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection.
Input power factor correctionMinimizes installation costs by enabling the use of smaller generators and cabling.
Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.
LCD displayAlpha-Numeric Display which displays system parameters and alarms.
Serial connectivityProvides management of the UPS via a serial port.
USB connectivityProvides management of the UPS via a USB port (not available on all models).
FeaturesManagement SoftwareAllows you to easily monitor your utility power and manage your UPS.
ECO ModeOperating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection.
Input power factor correctionMinimizes installation costs by enabling the use of smaller generators and cabling.
High efficiencyHigh efficiency rates that remain stable even at lower operating power levels.
SmartSlotCustomize UPS capabilities with management cards.
Intuitive LCD interfaceProvides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
Double conversion on-line topologyGuarantees a consistently high level of power quality. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source.
Generator compatibleEnsures clean, uninterrupted power to protected equipment when generator power is used.
Wide input voltage rangeDesigned for harsh electrical environments to save battery life.
ServiceabilityDisconnected battery notificationWarns when a battery is not available to provide backup power.
Audible alarmsProvides notification of changing utility power and UPS power conditions.
Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.
Predicitive failure notificationProvides early-warning fault analysis ensuring proactive component replacement.
ManageabilitySerial connectivityProvides management of the UPS via a serial port.
SmartSlotCustomize UPS capabilities with management cards.
LCD graphics displayText and mimic diagrams that display modes of operation, system parameters and alarms.
Network manageableProvides remote power management of the UPS over the network.
LED IndicatorsProvide easy-to-read status of the unit and utility power conditions.
AvailabilityIntelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.
APC SRV3KRI. UPS topology: Double-conversion (Online), Output power capacity: 3 kVA, Output power: 2400 W. AC outlet types: C13 coupler, C19 coupler, AC outlets quantity: 7 AC outlet(s), USB port type: USB Type-B. Battery technology: Sealed Lead Acid (VRLA), Battery recharge time: 4 h. Form factor: Rackmount, Product color: Black, Rack capacity: 1U. Compliance certificates: RoHS, Certification: CE, IEC 62040-1-1, IEC 62040-1-2 REACH
| UPS topology | Double-conversion (Online) |
| Output power capacity | 3 kVA |
| Output power | 2400 W |
| Waveform | Sine |
| Input operation voltage (min) | 160 V |
| Input operation voltage (max) | 280 V |
| Input frequency | 40/70 Hz |
| Output operation voltage (min) | 220 V |
| Output operation voltage (max) | 240 V |
| Output frequency | 50/60 Hz |
| Output voltage regulation | 1% |
| Surge energy rating | 600 J |
| Transfer time (Line Mode to Battery Mode) | 0 ms |
| Number of input phases | 1 |
| Number of output phases | 1 |
| Efficiency | 88% |
| Input power factor | 0.95 |
| Output power factor | 0.8 |
| Crest factor | 3:1 |
| ECO mode | Yes |
| Emergency Power Off (EPO) | No |
| Output voltage Total Harmonic Distortion (THD) | 3% |
| Noise level | 50 dB |
| Audible alarm(s) | Yes |
| Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
| Auto-restart | Yes |
| Maintenance-free | Yes |
| Socket circuit breaker | Yes |
| AC outlet types | C13 coupler, C19 coupler |
| AC outlets quantity | 7 AC outlet(s) |
| USB port | Yes |
| USB port type | USB Type-B |
| Serial interface | Yes |
| Serial ports quantity | 1 |
| SmartSlot | Yes |
| Battery technology | Sealed Lead Acid (VRLA) |
| Battery recharge time | 4 h |
| Automatic battery test | Yes |
| Form factor | Rackmount |
| Product color | Black |
| Rack capacity | 1U |
| Display type | LCD |
| LED indicators | Yes |
| Operating temperature (T-T) | 0 - 40 °C |
| Storage temperature (T-T) | -20 - 50 °C |
| Operating relative humidity (H-H) | 0 - 95% |
| Storage relative humidity (H-H) | 0 - 95% |
| Operating altitude | 0 - 118110.2" (0 - 3000 m) |
| Non-operating altitude | 0 - 581244.1" (0 - 14763.6 m) |
| Compliance certificates | RoHS |
| Certification | CE, IEC 62040-1-1, IEC 62040-1-2
REACH |
| Cables included | USB cable |
| Manual | Yes |
| Width | 17.2" (437 mm) |
| Depth | 24.9" (632 mm) |
| Height | 3.39" (86 mm) |
| Weight | 60.8 lbs (27.6 kg) |
| Software CD | Yes |
| Package width | 22.4" (569 mm) |
| Package depth | 31.3" (795 mm) |
| Package height | 9.02" (229 mm) |
| Package weight | 63.9 lbs (29 kg) |
| Harmonized System (HS) code | 85078000 |
| Nominal output voltage | 230 V |
| Nominal input voltage | 230 V |